| 摘要 | 第1-4页 |
| Abstract | 第4-10页 |
| 第1章 Introduction | 第10-34页 |
| ·Main facts and trends regarding non-residential buildings and of offices in China | 第10-13页 |
| ·The issue of comfort | 第13-20页 |
| ·Why comfort? | 第13-15页 |
| ·The traditional approach to thermal comfort in the built environment | 第15-18页 |
| ·Natural ventilation and the theory of adaptive comfort | 第18-20页 |
| ·The case of subtropical/tropical climates | 第20-32页 |
| ·Issues specific to subtropical/tropical climates | 第21-23页 |
| ·Learning from the ancients? | 第23-28页 |
| ·Thermalstrategiesofvernaculardwellingsinthesubtropicalareas of China | 第23-27页 |
| ·A model applicable to the design of modern office buildings? | 第27-28页 |
| ·Daytime natural ventilation in subtropical climates | 第28-32页 |
| ·Limitations of current natural ventilation standards | 第28-29页 |
| ·Natural ventilation in subtropical areas | 第29-31页 |
| ·Natural ventilation: to what purpose? | 第31-32页 |
| ·Mixed mode buildings as a feasible solution for extreme climates | 第32页 |
| ·Purpose and content of the study | 第32-34页 |
| 第2章 Presentation of the case building | 第34-55页 |
| ·Climate of China and Shenzhen | 第34-41页 |
| ·Climatic zones of China | 第34-38页 |
| ·The subtropical climate of Shenzhen | 第38-41页 |
| ·Building location and orientation | 第41-42页 |
| ·General description of the building | 第42-48页 |
| ·Air conditioning system | 第48-51页 |
| ·System description | 第48-49页 |
| ·Mode of operation | 第49-51页 |
| ·An architectural alternative to the traditional office building | 第51-55页 |
| 第3章 Indoor environment and comfort in the office spaces of the building | 第55-76页 |
| ·Measurements effected | 第55-58页 |
| ·Indoor environment | 第58-65页 |
| ·Temporal evolution of indoor parameters | 第58-59页 |
| ·Relationship between indoor and outdoor temperatures during working hours | 第59-61页 |
| ·Statistics on the physical parameters | 第61-63页 |
| ·Accordance with the standard ASHRAE 55 | 第63-64页 |
| ·Air velocities in the office room | 第64-65页 |
| ·Comfort assessment by occupants | 第65-72页 |
| ·Structure of the answer set | 第65页 |
| ·Global comfort and acceptability | 第65-68页 |
| ·Determinants of acceptability | 第68页 |
| ·Thermal sensation and expectation | 第68-69页 |
| ·humidity and wind velocity | 第69-71页 |
| ·Comfort during the NV autumn period | 第71-72页 |
| ·Use of different environment control systems | 第72-74页 |
| ·Clothing | 第72页 |
| ·Use of electric fans | 第72-73页 |
| ·Use of windows | 第73-74页 |
| ·Conclusion | 第74-76页 |
| 第4章 Electricity consumption of the building | 第76-105页 |
| ·Data collection and treatment | 第77-81页 |
| ·Nature of the source material used | 第77-78页 |
| ·Data treatment | 第78-81页 |
| ·Use of data from the power bills | 第78-79页 |
| ·Consistency check of the monitoring systems’ data and construc-tion of a reliable composite data set | 第79-81页 |
| ·Electricity consumption of the building | 第81-86页 |
| ·Final data set | 第81-82页 |
| ·Electricity consumption of the entire building | 第82-84页 |
| ·Breakdown of AC energy consumption | 第84-86页 |
| ·Comparison with other office buildings | 第86-90页 |
| ·Equivalent office building | 第86页 |
| ·Comparison of yearly and monthly consumption levels | 第86-89页 |
| ·Breakdown energy consumption comparison | 第89-90页 |
| ·Analysis of the energy saving performance through simulation | 第90-105页 |
| ·Construction of the DeST model | 第91页 |
| ·Preparatory on-site investigation | 第91-101页 |
| ·Characteristics of the simplified model | 第93-96页 |
| ·Fine-tuning of the model | 第96-100页 |
| ·Comparison cases | 第100-101页 |
| ·Results of the simulation analysis | 第101-105页 |
| 第5章 Conclusion | 第105-112页 |
| ·Background | 第105-106页 |
| ·Contents of the work realized | 第106-107页 |
| ·Main results | 第107-109页 |
| ·Indoor environment and comfort | 第107-108页 |
| ·Electricity consumption and energy saving | 第108-109页 |
| ·General conclusion and future work directions | 第109-112页 |
| 参考文献 | 第112-116页 |
| 致谢 | 第116-118页 |
| 个人简历、在学期间发表的学术论文与研究成果 | 第118页 |