| Abstract | 第1-4页 |
| 摘要 | 第4-10页 |
| 1. Introduction | 第10-39页 |
| ·Context | 第10-11页 |
| ·PV/T concepts and technology | 第11-19页 |
| ·What is a PV/T system and why has it been designed? | 第11-12页 |
| ·PV/T design concepts | 第12-16页 |
| ·Applications | 第16-19页 |
| ·State-of-the-art of PV/T technology | 第19-37页 |
| ·History and statistics | 第19-20页 |
| ·Purpose of the research | 第20-21页 |
| ·Theoretical and numerical research | 第21页 |
| ·Computational simulations | 第21-22页 |
| ·Experimental work | 第22-29页 |
| ·Economic studies | 第29-34页 |
| ·Main conclusions | 第34-36页 |
| ·Commercial development | 第36页 |
| ·Further R&D aspects for PV/T systems | 第36-37页 |
| ·Purpose of the present thesis | 第37-39页 |
| 2. Technical performance evaluation | 第39-56页 |
| ·Description of the experimental rig and measurement system | 第39-45页 |
| ·Description of the experimental rig | 第39-40页 |
| ·Description of the data acquisition system | 第40页 |
| ·Restoration work | 第40-43页 |
| ·Modifications for freeze prevention | 第43-45页 |
| ·Experimental conditions | 第45-46页 |
| ·Issues encountered | 第46-47页 |
| ·Experimental results and discussion | 第47-55页 |
| ·Climatic conditions of Beijing | 第47-48页 |
| ·Thermal performances | 第48-49页 |
| ·Electrical performances | 第49-52页 |
| ·Energy production for domestic hot water production | 第52-55页 |
| ·Main conclusions | 第55-56页 |
| 3. Economic evaluation | 第56-67页 |
| ·Method and formulas | 第56-57页 |
| ·Present worth | 第56页 |
| ·Equal-payment-series present worth factor | 第56-57页 |
| ·Equivalence under inflation | 第57页 |
| ·Economic evaluation of the system | 第57-66页 |
| ·Reference case assumptions | 第57-58页 |
| ·Estimation of the present costs of the system | 第58-59页 |
| ·Estimation of the annual savings | 第59-60页 |
| ·Calculation of the cost payback time and discussion | 第60-61页 |
| ·Discussion and comparison with previous economic studies | 第61-66页 |
| ·Main conclusions | 第66-67页 |
| 4. Sensitivity analysis | 第67-74页 |
| ·Influence of the present costs | 第67-70页 |
| ·Influence of the replacement costs | 第67-68页 |
| ·Influence of government financial incentives | 第68页 |
| ·Sensitivity to the PV module costs | 第68-69页 |
| ·Sensitivity to the frequency of components replacements | 第69-70页 |
| ·Influence of the annual savings | 第70-72页 |
| ·Sensitivity to the energy prices | 第70-71页 |
| ·Sensitivity to the PV cells efficiency | 第71-72页 |
| ·Combination of parameters | 第72页 |
| ·Main conclusions and suggestions | 第72-74页 |
| 5. Conclusions and recommendations | 第74-76页 |
| ·Conclusions | 第74页 |
| ·Recommendations for a future work | 第74-76页 |
| References | 第76-81页 |
| Acknowledgments | 第81-82页 |
| 个人简历、在学期间发表的学术论文与研究成果 | 第82-83页 |
| Appendix A: Calculation of the pumping power required to circulate the fluid through the system: | 第83-85页 |
| Appendix B: Uncertainties in the experimental measurements | 第85-87页 |
| Appendix C: Calculation of the batteries capacity | 第87页 |