| 摘要 | 第5-6页 |
| Abstract | 第6页 |
| Chapter 1 General introduction | 第10-35页 |
| 1.1 Research background and significance on power transformer bushing insulation | 第10-11页 |
| 1.2 Current research status of oil impregnated busing insulation | 第11-31页 |
| 1.2.1 Bushing design theory | 第12-15页 |
| 1.2.2 Moisture ingress and bushing failure mechanisms | 第15-19页 |
| 1.2.2.1 Moisture ingress | 第15-18页 |
| 1.2.2.2 Bushing failure mechanisms | 第18-19页 |
| 1.2.3 Moisture influence in oil-paper systems | 第19-24页 |
| 1.2.3.1 Moisture in oil | 第19-23页 |
| 1.2.3.2 Moisture in Paper | 第23-24页 |
| 1.2.4 Insulation Diagnostic methods | 第24-27页 |
| 1.2.5 Partial discharge theory | 第27-31页 |
| 1.2.5.1 External partial discharge | 第27-28页 |
| 1.2.5.2 Internal partial discharge | 第28页 |
| 1.2.5.3 Different terms used in partial discharge | 第28-29页 |
| 1.2.5.4 Moisture and PD Process within model | 第29-31页 |
| 1.2.5.5 Phase of PD development | 第31页 |
| 1.3 Aim | 第31-32页 |
| 1.4 Methods | 第32页 |
| 1.5 Research objectives and scope | 第32-33页 |
| 1.5.1 Objectives | 第32-33页 |
| 1.5.2 Scope | 第33页 |
| 1.6 Thesis outlines | 第33-35页 |
| Chapter 2 Test device and research methodology | 第35-44页 |
| 2.1 Introduction | 第35页 |
| 2.2 Test platform | 第35-39页 |
| 2.2.1 Power supply | 第35-36页 |
| 2.2.2 Detection device | 第36-38页 |
| 2.2.3 Calibration | 第38-39页 |
| 2.3 Specimen preparation and experiment Tools | 第39-41页 |
| 2.3.1 Specimen preparation | 第39-40页 |
| 2.3.2 Experiment tools | 第40-41页 |
| 2.4 Test method | 第41-42页 |
| 2.4.1 Partial discharge signal analysis method | 第41页 |
| 2.4.2 The process of experiment | 第41-42页 |
| 2.5 The problem of noise | 第42-43页 |
| 2.6 The summary of this chapter | 第43-44页 |
| Chapter 3 Moisture ingress process and PD phenomenon to bushing | 第44-49页 |
| 3.1 Introduction | 第44页 |
| 3.2 Moisture ingress | 第44-45页 |
| 3.3 Moisture characteristic on upper and lower parts of bushing model | 第45-46页 |
| 3.4 Influence of moisture on foil edge of oil impregnated bushing | 第46-47页 |
| 3.4.1 with constant voltage applied | 第46页 |
| 3.4.2 With electrical stress applied in steps | 第46-47页 |
| 3.5 Moisture location position effect and its impact on PD | 第47-48页 |
| 3.6 PD process and phenomenon poor-dry defect for bushing model | 第48页 |
| 3.7 The summary of this chapter | 第48-49页 |
| Chapter 4 Analysis of moisture effect in bushing | 第49-70页 |
| 4.1 Ingress using humidifier test results | 第49-50页 |
| 4.2 At different parts of bushing model moisture effect test result | 第50-52页 |
| 4.3 At constant voltage applied test result | 第52-54页 |
| 4.4 At electrical stress applied in steps test result | 第54-59页 |
| 4.5 Effect of moisture summary | 第59页 |
| 4.6 Paper moisture with injecting point | 第59-60页 |
| 4.7 Moisture location position effect and its impact on PD test results | 第60-70页 |
| 4.7.1 Horizontal (radial) water inject PD Development with voltage steps | 第61-62页 |
| 4.7.2 Vertical (axial) water inject on paper PD Development | 第62-63页 |
| 4.7.3 Horizontal and vertical PD Shape comparison | 第63-65页 |
| 4.7.4 Capacitance and dissipation factor characterizing insulation systems with moisture | 第65-70页 |
| Chapter 5 Conclusion | 第70-72页 |
| Reference | 第72-77页 |
| ACKNOWLEDGEMENTS | 第77页 |